Blower(Hospital)1
Location
S.T.P
Status
Operational
Priority
P3 - Routine
Condition grade 5
Critical
1
2
3
4
5
FINDINGS & RECOMMENDED ACTION
- Unit has been detected for overheating due to various of possible reasons. - Unit rated at 3600 RPM - Actual RPM Measured > 3510 - Motor pulley-to-pulley Blower ratio: 17 cm / 16 cm - Expected blower RPM > 3729 RPM - Actual blower RPM > 3703 RPM - Slippage 0.7% - No overcurrent detected. Newly installed MAPRO ML65 blower with Electro Adda 15 kW motor observed operating with constant noise and vibration. Blower motor temperature recorded at 75°C, drive belts at 87°C and belt guard at 63°C, indicating elevated operating temperatures. Actual motor speed measured at 3,510 RPM and blower speed at 3,703 RPM, slightly exceeding the blower nameplate speed of 3,637 RPM. Discharge pressure observed exceeding the normal operating range during the first few minutes of startup before returning to normal conditions. Excessive belt tensioning, pulley misalignment or increased mechanical loading suspected to be contributing to overheating and vibration. Previously installed MAPNER blower with CEMER 15 kW motor operated with 6-hour changeover intervals without reported overheating issues, whereas the newly installed blowers require changeover approximately every 1 hour due to overheating concerns.
Technical Details
- System
- Utilities
- Category
- Sewage Treatment Plant
- Manufacturer
- MEB S.A
- Model
- E3G160M/2
- Serial Number
- U5902070
- Location
- S.T.P
Documents
0No documents attached.
Need to update this asset?
Sign in with your technician or administrator account. Your name and every changed field are added to the asset history.
Sign in to update